All Greenville zoning districts

CM zoning in City of Greenville

Campus, City of Greenville

CM allows single-family homes by right on lots of at least 10,000 square feet. Apartments are allowed by right.

Minimum lot
10,000 sf
Dwellings per lot
None set
Front setback
10 ft
Height limit
68 ft

What a parcel in CM holds

ParcelSingle-family lots
2 acres6
5 acres16
10 acres32
20 acres65

A clean parcel with no flood zone or wetland, with 25% of the land kept for streets and open space. Lots are the lower of the minimum lot size count and the density limit. A real parcel loses more to its shape, hazards, and frontage. Screen a real parcel for its count.

Uses

UseStatusSource
Single-family homesBy rightSec. 19-3.2.2 Use Table (row: Single-unit living)
ApartmentsBy rightSec. 19-3.2.2 Use Table (row: Multi-unit living)

Limits

LimitValueSource and notes
Minimum lot size10,000 sfSec. 19-2.9.2 (CM district standards)Minimum lot area for lots recorded after July 15, 2023 (Sec. 19-2.11.2.A); up to 10% relief by Sec. 6.2.14. The CM table prints "10,000" without a unit; read as square feet, consistent with the other district tables.
Minimum lot width100 ftSec. 19-2.9.2 (CM district standards)City lot width is "the length of primary street lot lines bounding a lot", measured along the primary street lot line(s) (Sec. 19-2.11.2.B), not at the building line. Applies to lots recorded after July 15, 2023; up to 10% relief by Sec. 6.2.14.
Density limitNoneNo dwellings-per-lot or units-per-acre cap in this district; density is limited by height, coverage, massing and parking.
Dwellings per lotNoneNo dwellings-per-lot or units-per-acre cap in this district; density is limited by height, coverage, massing and parking.
Front setback10 ftSec. 19-2.9.2 (CM district standards)
Side setback10 ftSec. 19-2.9.2 (CM district standards)
Rear setback10 ftSec. 19-2.9.2 (CM district standards)
Height limit68 ftSec. 19-2.9.2 (CM district standards)
Story limit5 storiesSec. 19-2.9.2 (CM district standards)
Lot coverage limit60%Sec. 19-2.9.2 (CM district standards)
Floor area ratio limitNoneThe Development Code has no floor area ratio standard; intensity is set by height, coverage, build-to and massing.
Parking per apartment1 spacesSec. 19-4.6.2.C.1 (parking table)Minimum. No minimum on lots in a Preservation (-P) overlay or with a landmark or listed historic building (Sec. 19-4.6.2.B.2).

Screen a parcel zoned CM

Search an address or parcel number. The screen loads the parcel, finds its district, removes setbacks, flood zones, and wetlands, and counts lots and apartments with these limits.

Screen a parcel Listing sheets for agents

Other City of Greenville districts

  • BG Business General
  • BH Business Heavy
  • IG Industrial General
  • IX Industrial Flex
  • MX-2 Mixed Use 2
  • MX-3 Mixed Use 3

Limits from the City of Greenville Development Code, read November 20, 2026. Source document. Ordinances change and overlays can add limits. Confirm the district and its limits with the City of Greenville Planning and Development office before you rely on them.